Leading Manufacturers, Exporters and Wholesaler of BC9404.1 Digital Din Rail Mounted Transmitter, BC9408.1 Digital Din Rail Mounted Transmitter, C3436 Digital Conductivity Transmitter, C3630 Digital Conductivity Transmitter, CL3630 Digital Chlorine Transmitter, Digital Two Wire Transmitter, mV3630 Digital Orp Transmitter and PH3630 Digital PH Transmitter from Ajmer.
This transmitter, powered by a voltage between 9 and 36 Vdc, provides an isolated 4-20 mA "current loop" analog output, an RS485 digital output and Modbus. The instrument uses 2 or 4 electrode conductivity cells (K = 0.1 - 0.5 - 1 - 10) and Pt100 RTD temperature sensors.The temperature coefficient and reference temperature are selectable by the operator.The calibration of the sensor and the configuration of thetransmitter can be done locally or remotely via the serialinterface. Its modularity, small size and the technology used make it suitable for measuring electrical conductivity in various process applications.
Transmitter powered by a voltage between 10 and 30 Vdc provides an isolated 4-20 mA "current loop" analog output. The instrument uses 2 or 4 electrode conductivity cells with K = 1.00 and Pt100 RTD temperature sensors.Transmitter provide accurate, low costmeasuring andcontrol for industrial process, water treatment and wastewaterapplications. Its modularity, small size and the technology used make it suitable for measuring electricalconductivity in various process applications
A Two wire transmitter designed for the continuous measurement of Chlorine in a general-purpose industrial environment. This transmitter series powered by voltage between 10-30 Vdc provides an isolated 4-20 mA "current loop" analog output and provides for the connection of selective membrane, potentiostatic or galvanic polarographic sensors. It is designed for manual and automatic temperature compensation. The instrument also provides temperature measurement.
Model 3436 Series is a Two-wire transmitter design for the continuous measurement of pH, ORP, Chlorine or Conductivity in a general-purpose industrial environment. This transmitter, powered by a voltage between 9 and 36 Vdc, provides an isolated 4-20 mA "current loop" analogue output, an RS485 digital output and Modbus .The instrument uses potentiostatic or polarographic membrane sensors and Pt100 RTD temperature sensors. Its modularity, small size and the technology used make it suitable for measuring oxidants in various process applications.
It is a Two wire transmitter designed for the continuous measurement of ORP in a general-purpose industrial environment. This transmitter series powered by voltage between 10-30 Vdc provides an isolated 4-20 mA "current loop" analog output. ORP transmitter uses ORP sensors and Pt100 RTD temperature sensors. Its modularity, small size and the technology used make it suitable for ORP measurements in various processapplications.
It is a Two wire transmitter designed for the continuous measurement of pH in a general-purpose industrial environment. This transmitter series powered by voltage between 10-30 Vdc provides an isolated 4-20 mA "current loop" analog output. pH transmitter uses pH sensors and Pt100 RTD temperature sensors. Its modularity, small size and the technology used make it suitable for pH measurements in various process applications.